SerVision Ltd.
Page 4
Connection
Type
Default
COM Port
Connector Pin
on Camera
Flat Cable
Wire
Description
1
1
TX -
RS 485
COM2
3*
5
TX +
* Some hardware may be 2 instead of 3, depending on HW type.
Connecting a PTZ Camera to SVG1000
To connect a single PTZ camera to an SVG unit:
1. Connect the wires of the flat ribbon cable to the connector pins of the
camera, as specified in Table 3.
2. Insert the D-type 9-pin connector into the appropriate COM port, as
specified in Table 3.
Table 3 - Wire connections (SVG1000)
Connection
Type
Default
COM Port
Connector Pin
on Camera
Flat Cable
Wire
Description
2
3
RXD
3
5
TXD
RS 232
COM1
5
9
GND
1
1
TX -
RS 485
COM2
2
2
TX +
Connecting a PTZ Camera to IVG400
To connect a single PTZ camera to an IVG unit:
1. Connect the wires of the flat ribbon cable to the connector pins of the
camera, as specified in Table 4.
2. Insert the D-type 9-pin connector into the appropriate COM port, as
specified in Table 4.
Table 4 - Wire connection (IVG)
Connection
Type
Default
COM Port
Connector Pin
on Camera
Flat Cable
Wire
Description
6
2
TX -
RS 485
COM2
7
4
TX +